<LOGO>
FM Transmitter Measurement Report
Created: 2025-01-10 02-08-12
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 4/5, 58 dBuV VOLTAGE
Pilot RDS Phase Difference
7.1 kHz 3.5 kHz 22 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
11 kHz 74 kHz 10006 5,2269
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
5,5 dBr 7,20 dBr 8,5 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 10 (Pop M) 1 0 0 5 2:08, 10.01.2025
RT
"VOLTAGE - Dance music "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 5/5 (58 dBuV) Max at: 74 kHz MIN: 11 kHz % above 75 kHz: 5,2269 Acquired: 2025/01/10 2:07:08 Total samples: 10006 Equivalent time: 0:08:20 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000
FM Scope MAX: 8,5 dBr MIN: 5,5 dBr AVE: 7,20 dBr % above 10,0 dBr: 0,0 Last value: 8,3 dBr (2025/01/10 2:07:08) Station: 96.90 MHz, signal: 4/5 (58 dBuV) 02:00 02:01 02:02 02:03 02:04 02:05 02:06 02:07 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality